Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.360
Filtrar
1.
Int J Mol Sci ; 25(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38612918

RESUMO

Patients with first-diagnosed atrial fibrillation (FDAF) exhibit major adverse cardiovascular events (MACEs) during follow-up. Preclinical models have demonstrated that thrombo-inflammation mediates adverse cardiac remodeling and atherothrombotic events. We have hypothesized that thrombin activity (FIIa) links coagulation with inflammation and cardiac fibrosis/dysfunction. Surrogate markers of the thrombo-inflammatory response in plasma have not been characterized in FDAF. In this prospective longitudinal study, patients presenting with FDAF (n = 80), and 20 matched controls, were included. FIIa generation and activity in plasma were increased in the patients with early AF compared to the patients with chronic cardiovascular disease without AF (controls; p < 0.0001). This increase was accompanied by elevated biomarkers (ELISA) of platelet and endothelial activation in plasma. Pro-inflammatory peripheral immune cells (TNF-α+ or IL-6+) that expressed FIIa-activated protease-activated receptor 1 (PAR1) (flow cytometry) circulated more frequently in patients with FDAF compared to the controls (p < 0.0001). FIIa activity correlated with cardiac fibrosis (collagen turnover) and cardiac dysfunction (NT-pro ANP/NT-pro BNP) surrogate markers. FIIa activity in plasma was higher in patients with FDAF who experienced MACE. Signaling via FIIa might be a presumed link between the coagulation system (tissue factor-FXa/FIIa-PAR1 axis), inflammation, and pro-fibrotic pathways (thrombo-inflammation) in FDAF.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Estudos Longitudinais , Estudos Prospectivos , Receptor PAR-1 , Biomarcadores , Fibrose
2.
BMC Neurol ; 24(1): 120, 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38605308

RESUMO

BACKGROUND: Atrial fibrillation (AF) screening after ischemic stroke or transient ischemic attack (TIA) is given high priority in clinical guidelines. However, patient selection, electrocardiogram (ECG) modality and screening duration remains undecided and current recommendations vary. METHODS: The aim of this study was to investigate the clinical practice of AF screening after ischemic stroke or TIA at Swedish stroke units. In collaboration with the stakeholders of the Swedish Stroke Register (Riksstroke) a digital survey was drafted, then tested and revised by three stroke consultants. The survey consisted of 17 multiple choice/ free text questions and was sent by e-mail to the medical directors at all stroke units in Sweden. RESULTS: All 72 stroke units in Sweden responded to the survey. Most stroke units reported that ≥ 75% of ischemic stroke (69/72 stroke units) or TIA patients (67/72 stroke units), without previously known AF, were screened for AF. Inpatient telemetry ECG was the method of first-choice in 81% of the units, but 7% reported lack of access. A variety of standard monitoring durations were used for inpatient telemetry ECG. The second most common choice was Holter ECG (17%), also with considerable variations in monitoring duration. Other AF screening modalities were used as a first-choice method (handheld and patch ECG) but less frequently. CONCLUSIONS: Clinical practice for AF screening after ischemic stroke or TIA differed between Swedish stroke units, both in choice of AF screening methods as well as in monitoring durations. There is an urgent need for evidence and evidence-based recommendations in this field. TRIAL REGISTRATION: Not applicable.


Assuntos
Fibrilação Atrial , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Ataque Isquêmico Transitório/complicações , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Suécia/epidemiologia , Eletrocardiografia Ambulatorial , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
3.
J Am Heart Assoc ; 13(8): e033740, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38597139

RESUMO

BACKGROUND: Periodontitis has not been recognized as a modifiable risk factor for atrial fibrillation (AF). This prospective nonrandomized study investigated whether periodontal treatment improves the AF ablation outcome. METHODS AND RESULTS: We prospectively enrolled 288 AF patients scheduled to undergo initial radiofrequency catheter ablation. Each patient underwent periodontal inflamed surface area (PISA; a quantitative index of periodontal inflammation) measurement. All eligible patients were recommended to receive periodontal treatment within the blanking period, and 97 consented. During the mean follow-up period of 507±256 days, 70 (24%) AF recurrences were documented. Patients who exhibited AF recurrences had a higher PISA than those who did not (456.8±403.5 versus 277.7±259.0 mm2, P=0.001). These patients were categorized into high-PISA (>615 mm2) and low-PISA (<615 mm2) groups according to the receiver operating characteristic analysis for AF recurrence (area under the curve, 0.611; sensitivity, 39%; specificity, 89%). A high PISA, as well as female sex, AF duration, and left atrial volume, were the statistically significant predicter for AF recurrence (hazard ratio [HR], 2.308 [95% CI, 1.234-4.315]; P=0.009). In patients with a high PISA, those who underwent periodontal treatment showed significantly fewer AF recurrences (P=0.01, log-rank test). The adjusted HR of periodontal treatment for AF recurrence was 0.393 (95% CI, 0.215-0.719; P=0.002). CONCLUSIONS: Periodontitis may serve as a modifiable risk factor for AF. PISA is a hallmark of AF recurrence, and periodontal treatment improves the AF ablation outcome, especially for those with poor periodontal condition.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Periodontite , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Prospectivos , Átrios do Coração , Ablação por Cateter/efeitos adversos , Recidiva , Resultado do Tratamento
4.
Medicine (Baltimore) ; 103(15): e37582, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608063

RESUMO

BACKGROUND: Atrial fibrillation (AF) is one of the most common clinical arrhythmias. This study aims to predict the risk of post-stroke AF through electrocardiographic changes in sinus rhythm. METHODS: We searched the MEDLINE (PubMed) and EMBASE databases to identify relevant research articles published until August 2023. Prioritized items from systematic reviews and meta-analyses were screened, and data related to AF detection rate were extracted. A meta-analysis using a random-effects model was conducted for data synthesis and analysis. RESULTS: A total of 32 studies involving electrocardiograms (ECG) were included, with a total analysis population of 330,284 individuals. Among them, 16,662 individuals (ECG abnormal group) developed AF, while 313,622 individuals (ECG normal group) did not. ECG patterns included terminal P-wave terminal force V1, interatrial block (IAB), advanced interatrial block, abnormal P-wave axis, pulse rate prolongation, and atrial premature complexes. Overall, 15,762 patients experienced AF during the study period (4.77%). In the ECG abnormal group, the proportion was 14.21% (2367/16,662), while in the control group (ECG normal group), the proportion was 4.27% (13,395/313,622). The pooled risk ratio for developing AF was 2.45 (95% confidence interval [CI]: 2.02-2.98, P < .001), with heterogeneity (I2) of 95%. The risk ratio values of alAB, P-wave terminal force V1, interatrial block, abnormal P-wave axis, pulse rate prolongation and atrial premature complexes were 4.12 (95% CI, 2.99-5.66), 1.47 (95% CI, 1.19-1.82), 2.54 (95% CI, 1.83-3.52), 1.70 (95% CI, 0.98-2.97), 2.65 (95% CI, 1.88-3.72), 3.79 (95% CI, 2.12-6.76), respectively. CONCLUSION: There is a significant correlation between ECG patterns and the occurrence of AF. The alAB exhibited the highest level of predictability for the occurrence of AF. These indicators support their use as screening tools to identify high-risk individuals who may benefit from further examinations or empirical anticoagulation therapy following stroke.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Bloqueio Interatrial , Revisões Sistemáticas como Assunto , Metanálise como Assunto , Frequência Cardíaca , Eletrocardiografia
7.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38571291

RESUMO

AIMS: Same-day discharge (SDD) after atrial fibrillation (AF) ablation is an effective means to spare healthcare resources. However, safety remains a concern, and besides structural adaptations, SDD requires more efficient logistics and coordination. Therefore, in this study, we implement a streamlined, nurse-coordinated SDD programme following a standardized protocol. METHODS AND RESULTS: As a dedicated SDD coordinator, a nurse specialized in ambulatory cardiac interventions was in charge of the full SDD protocol, including eligibility, patient flow, in-hospital logistics, patient education, and discharge as well as early post-discharge follow-up by smartphone-based virtual visits. Patients planned for AF ablation were considered eligible if they had a left ventricular ejection fraction (LVEF) ≥35%, with basic support at home and accessibility of the hospital within 60 min also forming a part of the eligibility criteria. A total of 420 consecutive patients were screened by the SDD coordinator, of whom 331 were eligible for SDD. The reasons for exclusion were living remotely (29, 6.9%), lack of support at home (19, 4.5%), or LVEF <35% (17, 4.0%). Of the eligible patients, 300 (91%) were successfully discharged the same day. There were no major post-SDD complications. Rates of unplanned medical attention (19, 6.3%) and 30-day readmission (5, 1.6%) were extremely low and driven by femoral access-site complications. These were significantly reduced upon the introduction of compulsory ultrasound-guided punctures after the initial 150 SDD patients (P = 0.0145). Standardized SDD coordination resulted in efficient workflows and reduced the total workload of the medical staff. CONCLUSION: Same-day discharge after AF ablation following a nurse-coordinated standardized protocol is safe and efficient. The concept of ambulatory cardiac intervention nurses functioning as dedicated coordinators may be key in the future transition of hospitals to SDD. Ultrasound-guided femoral puncture virtually eliminated relevant femoral access-site complications in our cohort and should therefore be a prerequisite for SDD.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Alta do Paciente , Volume Sistólico , Assistência ao Convalescente , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
8.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584395

RESUMO

AIMS: A few studies have reported the effect and safety of pulsed field ablation (PFA) catheters for ablating atrial fibrillation (AF), which were mainly based on basket-shaped or flower-shaped designs. However, the clinical application of a circular-shaped multi-electrode catheter with magnetic sensors is very limited. To study the efficacy and safety of a PFA system in patients with paroxysmal AF using a circular-shaped multi-electrode catheter equipped with magnetic sensors for pulmonary vein isolation (PVI). METHODS AND RESULTS: A novel proprietary bipolar PFA system was used for PVI, which utilized a circular-shaped multi-electrode catheter with magnetic sensors and allowed for three-dimensional model reconstruction, mapping, and ablation in one map. To evaluate the efficacy, efficiency, and safety of this PFA system, a prospective, multi-centre, single-armed, pre-market clinical study was performed. From July 2021 to December 2022, 151 patients with paroxysmal AF were included and underwent PVI. The study examined procedure time, immediate success rate, procedural success rate at 12 months, and relevant complications. In all 151 patients, all the pulmonary veins were acutely isolated using the studied system. Pulsed field ablation delivery was 78.4 ± 41.8 times and 31.3 ± 16.7 ms per patient. Skin-to-skin procedure time was 74.2 ± 29.8 min, and fluoroscopy time was 13.1 ± 7.6 min. The initial 11 (7.2%) cases underwent procedures with deep sedation anaesthesia, and the following cases underwent local anaesthesia. In the initial 11 cases, 4 cases (36.4%) presented transient vagal responses, and the rest were all successfully preventatively treated with atropine injection and rapid fluid infusion. No severe complications were found during or after the procedure. During follow-up, 3 cases experienced atrial flutter, and 11 cases had AF recurrence. The estimated 12-month Kaplan-Meier of freedom from arrhythmia was 88.4%. CONCLUSION: The PFA system, comprised of a circular PFA catheter with magnetic sensors, could rapidly achieve PVI under three-dimensional guidance and demonstrated excellent safety with comparable effects.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Estudos Prospectivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Cateteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fenômenos Magnéticos , Recidiva
9.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Cateteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
J Cardiothorac Surg ; 19(1): 190, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589914

RESUMO

OBJECTIVES: Although risk factors for unsuccessful Maze procedure have been demonstrated, an appropriate patient selection is still controversial. In our institute, Maze procedure is indicated for those whom normal sinus rhythm (NSR) was reestablished by intraoperative direct cardioversion (DC) after ventricular unloading by total cardiopulmonary bypass. The purpose of this study was to evaluate the effectiveness of our indication criteria for Maze procedure in patients with mitral valve disease. METHODS: Between October 2012 and October 2021, MAZE was indicated in 55 patients in whom normal sinus rhythm (NSR) was reestablished by intraoperative direct current cardioversion (DC). Three endpoints and predictors were examined: disappearance of atrial fibrillation (AF), NSR, and A-wave detection. RESULTS: Restoration of NSR by intraoperative DC was confirmed in 43 patients, and these patients underwent MAZE. AF disappeared in 39 patients (90.7%), and F-wave ≥ 0.1 mV was a significant predictive factor (odds ratio (OR) 20.99, 95% CI 1.22-1079.06). NSR was reestablished in 36 patients (83.7%), and F-wave ≥ 0.1 mV (odds ratio 15.62, 95% CI 1.62-359.86) + AF history ≤ 3 years (OR 8.30, 95% CI 1.09-177.04) were significant predictors. A-wave detection was confirmed in 26 patients (60.5%), and left atrial diameter ≤ 55 mm was a significant predictor (OR 5.22, 95% CI 1.28-24.79). CONCLUSIONS: Intraoperative DC after ventricular unloading resulted effective patient selection for concomitant Maze procedure. F-wave and AF history were predictive factor of electrical restoration of AF, and left atrial diameter was predictive factor of restoration of atrial function.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doenças das Valvas Cardíacas , Insuficiência da Valva Mitral , Estenose da Valva Mitral , Humanos , Valva Mitral/cirurgia , Procedimento do Labirinto , Seleção de Pacientes , Estenose da Valva Mitral/cirurgia , Resultado do Tratamento , Doenças das Valvas Cardíacas/complicações , Fibrilação Atrial/diagnóstico , Ablação por Cateter/métodos
11.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38591838

RESUMO

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Risco , Hemorragia , Anticoagulantes/uso terapêutico
12.
PLoS One ; 19(4): e0297551, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38593145

RESUMO

Arrhythmia is a life-threatening cardiac condition characterized by irregular heart rhythm. Early and accurate detection is crucial for effective treatment. However, single-lead electrocardiogram (ECG) methods have limited sensitivity and specificity. This study propose an improved ensemble learning approach for arrhythmia detection using multi-lead ECG data. Proposed method, based on a boosting algorithm, namely Fine Tuned Boosting (FTBO) model detects multiple arrhythmia classes. For the feature extraction, introduce a new technique that utilizes a sliding window with a window size of 5 R-peaks. This study compared it with other models, including bagging and stacking, and assessed the impact of parameter tuning. Rigorous experiments on the MIT-BIH arrhythmia database focused on Premature Ventricular Contraction (PVC), Atrial Premature Contraction (PAC), and Atrial Fibrillation (AF) have been performed. The results showed that the proposed method achieved high sensitivity, specificity, and accuracy for all three classes of arrhythmia. It accurately detected Atrial Fibrillation (AF) with 100% sensitivity and specificity. For Premature Ventricular Contraction (PVC) detection, it achieved 99% sensitivity and specificity in both leads. Similarly, for Atrial Premature Contraction (PAC) detection, proposed method achieved almost 96% sensitivity and specificity in both leads. The proposed method shows great potential for early arrhythmia detection using multi-lead ECG data.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Complexos Ventriculares Prematuros/diagnóstico , Eletrocardiografia/métodos , Algoritmos , Complexos Atriais Prematuros/diagnóstico , Aprendizado de Máquina
13.
Kardiologiia ; 64(3): 25-33, 2024 Mar 31.
Artigo em Russo, Inglês | MEDLINE | ID: mdl-38597759

RESUMO

AIM: To determine predictors for the development of atrial fibrillation (AF) in patients with chronic heart failure (CHF) with preserved and reduced ejection fraction by echocardiography (EchoCG) according to an extended protocol with determination of diastolic function and left atrial global strain. MATERIAL AND METHODS: Data of 168 patients with stage I-III CHF without a history of AF were analyzed. All patients underwent echocardiography according to an extended protocol with the determination of diastolic dysfunction (DD), left atrial ejection fraction (LA EF), and left atrial global strain (LA GS). Tissue Doppler imaging (TDI) was used to evaluate the early (E) and late (A) LV filling velocity and the early (E') and late (A') diastolic mitral annular velocity. In all patients, Holter ECG monitoring (HM ECG) of heart rhythm was performed for 3 days, and ECG monitoring with telemedicine technologies was performed for 7 days, 3 times a day for 3 minutes. The follow-up period was 3 months or until an AF episode. RESULTS: During the study, paroxysmal AF (pAF) was detected in 41 (24.4%) patients using various methods of heart rhythm monitoring. Complaints of palpitations were noted for 10 (24.4%) patients during pAF, which was recorded using a CardioQVARK® device, HM ECG or a 12-lead ECG. In 5 (12.2%) patients, daily ECG monitoring revealed pAF without associated complaints. HM ECG detected 8, 2, 4 (19.5%, 4.8%, and 9.7%) cases during 24, 48 and 72 hours, respectively; a single-channel CardioQVARK® detected 30 (73.2%) cases when used 3 times a day for 7 days. These results showed that AF frequently develops in CHF without accompanying symptoms. The method for detecting pAF with CardioQVARK® showed good results: it was twice more effective than HM ECG and three times more effective than 12-lead ECG. Also, according to ultrasound data, significant changes in the following parameters were noted in patients with AF: LA EF <36% (OR 1.04, 95% CI: 1.02-1.08), p=0.003; LA GS <9.9% (OR 1.16, 95% CI: 1.02-1.38), p<0.001; TDI E med <5.7 cm/s (OR 0.97, 95% CI: 0.94-1.00), p=0.026. Grade 2 DD did not show statistically significant results (OR 1.1, 95% CI: 0.7-1.5, p=0.54). However, it was detected more frequently in patients with AF, in 34% of cases, compared to 29% of cases in patients without AF, which requires further study on a larger patient sample. CONCLUSION: Patients with CHF have a high risk of developing pAF (24.4%). 75% of patients with AF do not feel the development of paroxysm. All CHF patients should undergo EchoCG with assessment of LA EF, TDI E med and LA GS to identify a group at risk for the development of AF. Heart rhythm remote monitoring with CardioQVARK® devices can be considered a reliable method for early detection of pAF and timely initiation of anticoagulant therapy in patients with CHF.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Volume Sistólico , Eletrocardiografia , Átrios do Coração , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Doença Crônica
14.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38597211

RESUMO

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Fenótipo , Recidiva , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
15.
PLoS One ; 19(4): e0301991, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38626094

RESUMO

The aim of this study is to define atrial fibrillation (AF) prevalence and incidence rates across minority groups in the United States (US), to aid in diversity enrollment target setting for randomized controlled trials. In AF, US minority groups have lower clinically detected prevalence compared to the non-Hispanic or Latino White (NHW) population. We assess the impact of ascertainment bias on AF prevalence estimates. We analyzed data from adults in Optum's de-identified Clinformatics® Data Mart Database from 2017-2020 in a cohort study. Presence of AF at baseline was identified from inpatient and/or outpatient encounters claims using validated ICD-10-CM diagnosis algorithms. AF incidence and prevalence rates were determined both in the overall population, as well as in a population with a recent stroke event, where monitoring for AF is assumed. Differences in prevalence across cohorts were assessed to determine if ascertainment bias contributes to the variation in AF prevalence across US minority groups. The period prevalence was respectively 4.9%, 3.2%, 2.1% and 5.9% in the Black or African American, Asian, Hispanic or Latino, and NHW population. In patients with recent ischemic stroke, the proportion with AF was 32.2%, 24.3%, 25%, and 24.5%, respectively. The prevalence of AF among the stroke population was approximately 7 to 10 times higher than the prevalence among the overall population for the Asian and Hispanic or Latino population, compared to approximately 5 times higher for NHW patients. The relative AF prevalence difference of the Asian and Hispanic or Latino population with the NHW population narrowed from respectively, -46% and -65%, to -22% and -24%. The study findings align with previous observational studies, revealing lower incidence and prevalence rates of AF in US minority groups. Prevalence estimates of the adult population, when routine clinical practice is assumed, exhibit higher prevalence differences compared to settings in which monitoring for AF is assumed, particularly among Asian and Hispanic or Latino subgroups.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Adulto , Humanos , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Hispânico ou Latino , Grupos Minoritários , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/epidemiologia , Estados Unidos/epidemiologia , Negro ou Afro-Americano , Asiático , Brancos , Viés
16.
Radiol Cardiothorac Imaging ; 6(2): e230172, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38573128

RESUMO

Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.


Assuntos
Fibrilação Atrial , Diafragma , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Meios de Contraste , Gadolínio , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Feminino
17.
BMJ ; 385: e077209, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38631726

RESUMO

OBJECTIVES: To examine how the lifetime risks of atrial fibrillation and of complications after atrial fibrillation changed over time. DESIGN: Danish, nationwide, population based cohort study. SETTING: Population of Denmark from 1 January 2000 to 31 December 2022. PARTICIPANTS: 3.5 million individuals (51.7% women and 48.3% men) who did not have atrial fibrillation at 45 years of age or older were followed up until incident atrial fibrillation, migration, death, or end of follow-up, whichever came first. All 362 721 individuals with incident atrial fibrillation (46.4% women and 53.6% men), but with no prevalent complication, were further followed up until incident heart failure, stroke, or myocardial infarction. MAIN OUTCOME MEASURES: Lifetime risk of atrial fibrillation and lifetime risks of complications after atrial fibrillation over two prespecified periods (2000-10 v 2011-22). RESULTS: The lifetime risk of atrial fibrillation increased from 24.2% in 2000-10 to 30.9% in 2011-22 (difference 6.7% (95% confidence interval 6.5% to 6.8%)). After atrial fibrillation, the most frequent complication was heart failure with a lifetime risk of 42.9% in 2000-10 and 42.1% in 2011-22 (-0.8% (-3.8% to 2.2%)). Individuals with atrial fibrillation lost 14.4 years with no heart failure. The lifetime risks of stroke and of myocardial infarction after atrial fibrillation decreased slightly between the two periods, from 22.4% to 19.9% for stroke (-2.5% (-4.2% to -0.7%)) and from 13.7% to 9.8% for myocardial infarction (-3.9% (-5.3% to -2.4%). No evidence was reported of a differential decrease between men and women. CONCLUSION: Lifetime risk of atrial fibrillation increased over two decades of follow-up. In individuals with atrial fibrillation, about two in five developed heart failure and one in five had a stroke over their remaining lifetime after atrial fibrillation diagnosis, with no or only small improvement over time. Stroke risks and heart failure prevention strategies are needed for people with atrial fibrillation.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Infarto do Miocárdio , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Fatores de Risco , Incidência , Acidente Vascular Cerebral/epidemiologia , Infarto do Miocárdio/etiologia , Insuficiência Cardíaca/epidemiologia , Dinamarca/epidemiologia
18.
G Ital Cardiol (Rome) ; 25(5): 340-345, 2024 May.
Artigo em Italiano | MEDLINE | ID: mdl-38639124

RESUMO

BACKGROUND: Cancer is an important condition associated with the development of atrial fibrillation (AF). The objectives of the BLITZ-AF Cancer study were to collect real-life information on the clinical profile and use of antithrombotic drugs in patients with AF and cancer to improve clinical management, as well as the evaluation of the association between different antithrombotic treatments (or their absence) and the main clinical events. METHODS: European multinational, multicenter, prospective, non-interventional study conducted in patients with AF (electrocardiographically confirmed) and cancer occurring within 3 years. The CHA2DS2-VASc and the HAS-BLED scores were calculated in all enrolled patients. RESULTS: From June 2019 to July 2021, 1514 patients were enrolled, 36.5% women, from 112 cardiology departments in 6 European countries (Italy, Belgium, the Netherlands, Spain, Portugal and Ireland). Italy enrolled 971 patients in 77 centers. Average age of patients was 74 ± 9 years, of which 20.9% affected by heart failure, 18.1% by ischemic heart disease, 9.8% by peripheral arterial disease and 38.5% by valvular diseases; 41.5% of patients had a CHA2DS2-VASc score ≥4. The most represented cancer sites were lung (14.9%), colorectal tract (14.1%), prostate (8.8%), or non-Hodgkin's lymphoma (8.1%). Before enrollment, 16.6% of patients were not taking antithrombotic therapy, while 22.7% were on therapy with antiplatelet agents and/or low molecular weight heparin. After enrollment these percentages decreased to 7.7% and 16.6%, respectively and, at the same time, the percentage of patients on direct oral anticoagulant (DOAC) therapy increased from 48.4% to 68.4%, also to the detriment of those on vitamin K antagonist therapy. CONCLUSIONS: The BLITZ-AF Cancer study, which enrolled patients diagnosed with AF and cancer, highlights that the use of DOACs by cardiologists in this clinical context has increased, even though the guidelines on AF do not give accurate indications about oral anticoagulant therapy in patients with cancer.


Assuntos
Fibrilação Atrial , Neoplasias , Acidente Vascular Cerebral , Masculino , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/diagnóstico , Fibrinolíticos/uso terapêutico , Estudos Prospectivos , Anticoagulantes , Neoplasias/complicações , Acidente Vascular Cerebral/complicações , Fatores de Risco
19.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38630867

RESUMO

AIMS: Photoplethysmography- (PPG) based smartphone applications facilitate heart rate and rhythm monitoring in patients with paroxysmal and persistent atrial fibrillation (AF). Despite an endorsement from the European Heart Rhythm Association, validation studies in this setting are lacking. Therefore, we evaluated the accuracy of PPG-derived heart rate and rhythm classification in subjects with an established diagnosis of AF in unsupervised real-world conditions. METHODS AND RESULTS: Fifty consecutive patients were enrolled, 4 weeks before undergoing AF ablation. Patients used a handheld single-lead electrocardiography (ECG) device and a fingertip PPG smartphone application to record 3907 heart rhythm measurements twice daily during 8 weeks. The ECG was performed immediately before and after each PPG recording and was given a diagnosis by the majority of three blinded cardiologists. A consistent ECG diagnosis was exhibited along with PPG data of sufficient quality in 3407 measurements. A single measurement exhibited good quality more often with ECG (93.2%) compared to PPG (89.5%; P < 0.001). However, PPG signal quality improved to 96.6% with repeated measurements. Photoplethysmography-based detection of AF demonstrated excellent sensitivity [98.3%; confidence interval (CI): 96.7-99.9%], specificity (99.9%; CI: 99.8-100.0%), positive predictive value (99.6%; CI: 99.1-100.0%), and negative predictive value (99.6%; CI: 99.0-100.0%). Photoplethysmography underestimated the heart rate in AF with 6.6 b.p.m. (95% CI: 5.8 b.p.m. to 7.4 b.p.m.). Bland-Altman analysis revealed increased underestimation in high heart rates. The root mean square error was 11.8 b.p.m. CONCLUSION: Smartphone applications using PPG can be used to monitor patients with AF in unsupervised real-world conditions. The accuracy of AF detection algorithms in this setting is excellent, but PPG-derived heart rate may tend to underestimate higher heart rates.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Smartphone , Fotopletismografia , Frequência Cardíaca , Valor Preditivo dos Testes , Eletrocardiografia/métodos , Algoritmos
20.
Cardiovasc Diabetol ; 23(1): 121, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38581024

RESUMO

BACKGROUND: This study investigates the relationship between triglyceride-glucose (TyG) index trajectories and the results of ablation in patients with stage 3D atrial fibrillation (AF). METHODS: A retrospective cohort study was carried out on patients who underwent AF Radiofrequency Catheter Ablation (RFCA) at the Cardiology Department of the Fourth Affiliated Hospital of Zhejiang University and Taizhou Hospital of Zhejiang Province from January 2016 to December 2022. The main clinical endpoint was determined as the occurrence of atrial arrhythmia for at least 30 s following a 3-month period after ablation. Using a latent class trajectory model, different trajectory groups were identified based on TyG levels. The relationship between TyG trajectory and the outcome of AF recurrence in patients was assessed through Kaplan-Meier survival curve analysis and multivariable Cox proportional hazards regression model. RESULTS: The study included 997 participants, with an average age of 63.21 ± 9.84 years, of whom 630 were males (63.19%). The mean follow-up period for the participants was 30.43 ± 17.75 months, during which 200 individuals experienced AF recurrence. Utilizing the minimum Bayesian Information Criterion (BIC) and the maximum Entropy principle, TyG levels post-AF RFCA were divided into three groups: Locus 1 low-low group (n = 791), Locus 2 low-high-low group (n = 14), and Locus 3 high-high group (n = 192). Significant differences in survival rates among the different trajectories were observed through the Kaplan-Meier curve (P < 0.001). Multivariate Cox regression analysis showed a significant association between baseline TyG level and AF recurrence outcomes (HR = 1.255, 95% CI: 1.087-1.448). Patients with TyG levels above 9.37 had a higher risk of adverse outcomes compared to those with levels below 8.67 (HR = 2.056, 95% CI: 1.335-3.166). Furthermore, individuals in Locus 3 had a higher incidence of outcomes compared to those in Locus 1 (HR = 1.580, 95% CI: 1.146-2). CONCLUSION: The TyG trajectories in patients with stage 3D AF are significantly linked to the outcomes of AF recurrence. Continuous monitoring of TyG levels during follow-up may help in identifying patients at high risk of AF recurrence, enabling the early application of effective interventions.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Estudos Retrospectivos , Teorema de Bayes , Resultado do Tratamento , Fatores de Risco , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA